1 gener a l user p a ra met e rs – HEIDENHAIN iTNC 530 (340 49x-04) User Manual
Page 745

HEIDENHAIN iTNC 530
745
14.1 Gener
a
l User P
a
ra
met
e
rs
KinematicsOpt: Tolerance limit for error
message in Optimization mode
MP6600
0.001 to 0.999
KinematicsOpt: Maximum permitted
deviation from entered calibration sphere
radius
MP6601
0.01 to 0.1
TNC displays, TNC editor
Cycles 17, 18 and 207:
Oriented spindle stop
at beginning of cycle
MP7160
Oriented spindle stop: 0
No oriented spindle stop: 1
Programming station
MP7210
TNC with machine: 0
TNC as programming station with active PLC: 1
TNC as programming station with inactive PLC: 2
Acknowledgment of
POWER INTERRUPTED
after switch-on
MP7212
Acknowledge with key: 0
Acknowledge automatically: 1
ISO programming: Set
the block number
increment
MP7220
0 to 150
Disabling the selection
of file types
MP7224.0
All file types selectable via soft key: +0
Disable selection of HEIDENHAIN programs (soft key SHOW .H): +1
Disable selection of ISO programs (soft key SHOW .I): +2
Disable selection of tool tables (soft key SHOW .T): +4
Disable selection of datum tables (soft key SHOW .D): +8
Disable selection of pallet tables (soft key SHOW .P): +16
Disable selection of text files (soft key SHOW .A): +32
Disable selection of point tables (soft key SHOW .PNT): +64
Disabling the editor for
certain file types
Note:
If a particular file type is
inhibited, the TNC will
erase all files of this type.
MP7224.1
Do not disable editor: +0
Disable editor for
HEIDENHAIN programs: +1
ISO programs: +2
Tool tables: +4
Datum tables: +8
Pallet tables: +16
Text files: +32
Point tables: +64
3-D touch probes