KinematicsOpt: Tolerance limit for error
message in Optimization mode

MP6600
0.001
to 0.999

KinematicsOpt: Maximum permitted
deviation from entered calibration sphere
radius

MP6601
0.01
to 0.1

TNC displays, TNC editor

Cycles 17, 18 and 207:
Oriented spindle stop
at beginning of cycle

MP7160
Oriented spindle stop: 0
No oriented spindle stop: 1

Programming station

MP7210
TNC with machine: 0
TNC as programming station with active PLC: 1
TNC as programming station with inactive PLC: 2

Acknowledgment of
POWER INTERRUPTED
after switch-on

MP7212
Acknowledge with key: 0
Acknowledge automatically: 1

ISO programming: Set
the block number
increment

MP7220
0
to 150

Disabling the selection
of file types

MP7224.0
All file types selectable via soft key: +0
Disable selection of HEIDENHAIN programs (soft key SHOW .H): +1
Disable selection of ISO programs (soft key SHOW .I): +2
Disable selection of tool tables (soft key SHOW .T): +4
Disable selection of datum tables (soft key SHOW .D): +8
Disable selection of pallet tables (soft key SHOW .P): +16
Disable selection of text files (soft key SHOW .A): +32
Disable selection of point tables (soft key SHOW .PNT): +64

Disabling the editor for
certain file types

Note:

If a particular file type is
inhibited, the TNC will
erase all files of this type.

MP7224.1
Do not disable editor: +0
Disable editor for

„

HEIDENHAIN programs: +1

„

ISO programs: +2

„

Tool tables: +4

„

Datum tables: +8

„

Pallet tables: +16

„

Text files: +32

„

Point tables: +64

3-D touch probes