Leaving the pallet file, Executing the pallet file – HEIDENHAIN iTNC 530 (340 49x-04) User Manual
Page 193

HEIDENHAIN iTNC 530
193
4.15 P
a
llet Oper
ation with T
ool-Or
ient
e
d Mac
h
ining
If the entries TO or CTO for all workpieces within a group contain the
status ENDED, the next lines in the pallet file are run.
Leaving the pallet file
Press the PGM MGT soft key to call the file manager.
To select a different type of file, press the SELECT TYPE soft key
and the soft key for the desired file type, for example SHOW.H.
Select the desired file.
Executing the pallet file
Select the file manager in the Program Run, Full Sequence or
Program Run, Single Block operating modes: Press the PGM MGT
key.
To display all type .P files, press the soft keys SELECT TYPE and
SHOW .P.
Select the pallet table with the arrow keys and confirm with ENT.
To execute the pallet table: Press the NC Start button. The TNC
executes the pallets as set in MP7683.
In mid-program startup, only one tool-oriented machining
operation is possible. Subsequent pieces are machined
according to the method entered.
The value entered in the CTID field is stored for a
maximum of 2 weeks. Within this time the machining
process can be continued at the stored location. After this
time the value is deleted, in order to prevent large
amounts of unnecessary data on the hard disk.
The operating mode can be changed after executing a
group of entries with TO or CTO.
The following functions are not permitted:
Switching the traverse range
PLC datum shift
M118
In MP7683, set whether the pallet table is to be executed
blockwise or continuously (see “General User
Parameters” on page 740).
Provided that MP7246 is set so that the tool usage test is
active, you can monitor the tool service life for all tools
used in a pallet (see “Tool usage test” on page 683).