beautypg.com

Reset the plane function – HEIDENHAIN iTNC 530 (340 49x-04) User Manual

Page 546

background image

546

9 Programming: Special Functions

9.2 The PLANE F

unction: Tilting the W

o

rk

ing Plane (Sof

tw

ar

e

O

ption

1

)

Reset the PLANE function

Show the soft-key row with special functions.

Select special TNC functions: Press the SPECIAL TNC

FUNCTIONS soft key.

Select the PLANE function: Press the TILT

MACHINING PLANE soft key: The TNC displays the
available definition possibilities in the soft-key row.

Select the Reset function. This internally resets the

PLANE

function, but does not change the current axis

positions.

Specify whether the TNC should automatically move

the rotary axes to the default setting (MOVE or TURN) or
not (STAY) (see “Automatic positioning: MOVE/
TURN/STAY (entry is mandatory)” on page 560).

To terminate entry, press the END key.

Example: NC block

25 PLANE RESET MOVE SET-UP50 F1000

The PLANE RESET function resets the current PLANE
function—or an active Cycle 19—completely (angles = 0
and function is inactive). It does not need to be defined
more than once.