HEIDENHAIN iTNC 530 (340 49x-04) User Manual
Page 100

100
2 Manual Operation and Setup
2.6 Dynamic Collision Monit
o
ri
ng (Sof
tw
ar
e Option)
Error zone
Two objects monitored for collision are less than 2 mm from each
other. The error message displayed (the machine manufacturer
determines the exact text) always starts with this text string: |<>|. In
this state you can only traverse the axes after deactivating collision
monitoring.
Shift the soft-key row if necessary.
Select the menu for deactivating collision monitoring.
Select the Manual Operation menu item.
To deactivate collision monitoring, press the ENT key,
and the symbol for collision monitoring in the
operating mode display starts to flash.
Acknowledge the collision error message with the CE key.
Manually traverse the axes out of the danger zone. Pay attention to
the direction of traverse.
If applicable, remove the reason for the collision message.
To reactivate collision monitoring: Press the ENT key.
Risk of collision!
Remember to move the axes in the correct direction when
backing off from the workpiece. In this condition the TNC
does not monitor for collisions.
If you have deactivated the collision monitoring, the
symbol for collision monitoring flashes (see following
table).
Function
Symbol
Symbol that appears in the operating mode bar
when collision monitoring is not active.