3.47. HWMSettings

Description

General settings for Hardware Monitoring

Properties

EnableSensors

Enable/disable all HWM functionality. (Default: No)

SensorPollInterval

Sensor polling interval. (Default: 500)

MemoryPollInterval

Memory polling interval in minutes. (Default: 15)

MemoryUsePercent

Should mem monitor use percentage as unit for
monitoring, else it is megabyte. (Default: Yes)

MemoryLogRepetition

Should a log message be sent for each poll result
that is in the Alert, Critical or Warning level, or
should a log message only be sent when a new
level is reached. (Default: No)

MemoryAlertLevel

Alert log message if free memory is below this
value, disable by using 0. (Default: 0)

MemoryCriticalLevel

Critical log message if free memory is below this
value, disable by using 0. (Default: 0)

MemoryWarningLevel

Warning log message if free memory is below this
value, disable by using 0. (Default: 0)

Note

This object type does not have an identifier and is identified by the name of the type
only. There can only be one instance of this type.