3.47. HWMSettings
Description
General settings for Hardware Monitoring
Properties
EnableSensors
Enable/disable all HWM functionality. (Default: No)
SensorPollInterval
Sensor polling interval. (Default: 500)
MemoryPollInterval
Memory polling interval in minutes. (Default: 15)
MemoryUsePercent
Should mem monitor use percentage as unit for
monitoring, else it is megabyte. (Default: Yes)
MemoryLogRepetition
Should a log message be sent for each poll result
that is in the Alert, Critical or Warning level, or
should a log message only be sent when a new
level is reached. (Default: No)
MemoryAlertLevel
Alert log message if free memory is below this
value, disable by using 0. (Default: 0)
MemoryCriticalLevel
Critical log message if free memory is below this
value, disable by using 0. (Default: 0)
MemoryWarningLevel
Warning log message if free memory is below this
value, disable by using 0. (Default: 0)
Note
This object type does not have an identifier and is identified by the name of the type
only. There can only be one instance of this type.
Chapter 3: Configuration Reference