6 number of metering pulses, 7 tariff type, Number of metering pulses – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 89: Tariff type, Figure 7, Format of the number of metering pulses parameter, Figure 8, Format of the tariff parameter, Section, 6 on

background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

89

The first byte of the data field contains the message type (this is the message
type contained in the PAM e.g. IAM, REL) followed by the rest of the message

data which is encoded as it would appear in a message received from the

network.

‘Generic’ Charge message

The message data parameter may be used to convey the entire national

specific Charge message within the generic Charge message and the

information is sent in transparent format to the user (the ISPX1GOP_TX_CRG
circuit group option must be set).

The data field contains all the parameters contained within the Charge

message.

Unrecognised message

The message data parameter may be used by ISUP to signal the content of a

received unrecognized message to the user (depending on the setting of the

ISPGXOP_COMPAT circuit group option).

The first byte of the data field contains the message type.

6.7.6

Number of Metering Pulses

The number of metering pulses parameter is not defined by ITU-T. It is a

proprietary parameter which is used to convey a number of metering pulses.

The format of the parameter is as follows:

Figure 7.

Format of the Number of Metering Pulses Parameter

8 7 6 5 4 3 2 1

Name = 11111111 (255)

Length = 1

Number of metering pulses

6.7.7 Tariff

Type

The tariff type parameter is not defined by ITU-T. It is a proprietary

parameter which is used to convey a tariff type. The format of the parameter
is as follows:

Figure 8.

Format of the Tariff Parameter

8 7 6 5 4 3 2 1

Name = 11111110 (254)

Length = 1

1 Tariff

type