beautypg.com

3 ‘generic’ charge request, 4 circuit seized request, Generic’ charge request – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 31: Circuit seized request

background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

31

Optional parameters

• Message compatibility information
• Parameter compatibility information
• Application transport parameter

This parameter may be repeated (see

Appendix E: ISUP Repeat

Parameters on page 197

).

• End of optional parameter

6.5.3

‘Generic’ Charge Request

Note: This message is only applicable to ITU-T operation.

This primitive is used by the application to convey charging information

relating to a call. This message can be issued by the application in all call
states up to and including the answered and suspended states, provided that

the circuit group ISPX1GOP_TX_CRG option is set.

Message type

CRG (Charge Message)

Mandatory parameters

• Message data

Optional parameters

None

6.5.4

Circuit Seized Request

This primitive is used by the application to indicate that the circuit has been

seized for an outgoing call (but no address information has yet been sent)

and may be issued to initiate a continuity test call. When this primitive is
received by the ISUP module, a CCR message will be sent to the network.

Message type

SZE (Circuit Seized Message)

Mandatory parameters

• Nature of connection indicators

Optional parameters

None