2 circuit group supervision control request, Parameters, Circuit group supervision control request – Welltech Dialogic SS7 Protocols ISUP User Manual
Page 114
Section 7 Management Interface
114
7.2
Circuit Group Supervision Control Request
This message is issued by system management to initiate a circuit group
supervision control function. The functions supported are RESET, BLOCK
UNBLOCK and QUERY. The command operates on specified circuits within the
specified circuit group.
Message Header
structure
MSG
type
ISP_MSG_CGSC_REQ (0x7703)
id
gid
src
Originating module ID
dst
ISUP module ID
rsp_req
Sending layer's bit set if confirmation required
hclass
0x00
status
0x00
err_info
0x00
len
6
Parameter Area
offset 0, size 1
ptype
Management primitive type.
offset 1, size 1
reserved
reserved - must be set to zero
parameters
offset 2, size 4:
cic_mask
Bits set to indicate affected circuits in group.
ISUP Response
method
By returning the message to the sender
type
0x3703
status
SUCCESS
ISP_BAD_ID
ISP_BAD_PARAM
Parameters
gid
The group identifier for the Circuit Group.
ptype
The type of management primitive taken from the following table:
Value
Name
Function
0 Reset
Reset
circuit(s)
1
Stop Reset
Abort reset operation
Note: The circuits specified in this message must be identical to
those in the Reset Request message.
2
M-Block
Maintenance block circuit(s)