Welltech Dialogic SS7 Protocols ISUP User Manual
Page 179

Dialogic
®
SS7 Protocols ISUP Programmer's Manual Issue 15
179
Messages
Messages specific to China ISUP:
Message Value
China ISUP
API
Message Name
Message
Type
Hex
Dec
Hex
Dec
Usage
Comments
Calling Party Clearing
CCL
0xfc
252
0xcc
204
Sent in the forward
direction in the
answered state.
Refer to the more
extended options
(ISPX1GOP_CCL)
in
Section
.
Metering Pulse
MPM
0xfd
253
0xc9
201
Sent in the backward
direction in the
answered and
suspended states.
Operator
OPR
0xfe
254
0xcd
205
Sent in the forward
and backward
direction in the
answered state.
* Refer to
Section
6.6.24 Release Indication on page 71
Parameters
When this variant is selected, the following China ISUP specific parameters
may be used:
Parameter Value
China ISUP
API
Length
Parameter
Name
Hex
Dec
Hex
Dec
Mandatory/
Optional
Parameter
Min
Max
Message used
Comments
Charge
information
0xfd 254 0xca 202 Fixed
2 2
MPM
Message
compatibility
information*
0x38 56 0x38 56 Optional
1
1
CCL,MPM
OPR
* Refer to
Section