beautypg.com

Parameters, 5 circuit group supervision status indication, Circuit group supervision status indication – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 117

background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

117

Parameters

gid

The group identifier for the Circuit Group.

ptype

The type of management primitive taken from the following table:

Value

Name

Function

0 Reset

Circuit(s)

reset

2

M-Block

Circuit(s) maintenance blocked

3

M-Unblock

Circuit(s) maintenance unblocked

5

H-Block

Circuit(s) hardware blocked.

6

H-Unblock

Circuit(s) hardware unblocked

12

Available

The destination point code (signalilng point) for the circuits in
this group is now available.

13

Unavailable

The destination point code (signalling point) for the circuits in
this group has become temporarily unavailable.

cic_mask

A 32 bit mask indicating to which of the circuits in the circuit group the
message applies.

7.5

Circuit Group Supervision Status Indication

This message is issued by ISUP to indicate completion of a circuit group query
function requested by the user and contains the circuit state for the

requested circuits as provided by the remote signaling point.

Message Header

structure

MSG

type

ISP_MSG_CGSS_IND (0x070c)

id

gid

src

ISUP module ID

dst

Management module ID

rsp_req

0x00

hclass

0x00

status

0x00

err_info

0x00

len

38