Section 6 Interface to Application

66

Additional call information

This primitive is used by ISUP to indicate additional call information (other

than called address digits) during incoming call set-up.

Message type

INF (Information Message)

Mandatory parameters

• Information indicators

Optional parameters

• Access transport
• Calling party category
• Calling party number
• Call reference

The following optional parameters are supported in ITU mode only:

• Parameter compatibility information
• Network specific facility

The following optional parameters are supported in ANSI mode only:

• Business group
• Charge number
• Originating line information
• Redirecting number
• Redirection information
• User to user information

6.6.16

Loop Back Acknowledgement Indication

Loop back acknowledgement indication

This primitive is used by ISUP to indicate to the application that a continuity

check loop has been applied to the circuit. When an LPA message is received
from the network by the ISUP module, this primitive will be sent to the

application.

Message type

LPA (Loop Back Acknowledgement Message)