beautypg.com

19 maintenance event indication, Parameters, Maintenance event indication – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 158: Ction

background image

Section 8 Non-Primitive Interface

158

8.19

Maintenance Event Indication

This message is issued by the ISUP module to notify system maintenance of

various protocol events in accordance with ITU-T Q.764.

Message Header

structure

MSG

type

ISP_MSG_MAINT_IND (0x070a)

id

gid

src

ISUP module ID

dst

Maintenance module ID

rsp_req

0x00

hclass

0x00

status

Maintenance event code (see below)

err_info

Time-stamp

len

0, 1, 2 or 4

Parameter Area

parameters

offset 0, size Len

Event specific data

Parameters

gid

The group identifier for the Circuit Group.

Each indication may contain further Event Specific Data relating to the
event, this consists of 0, 1, 2 or 4 bytes of additional data which is contained

in the parameter area of the message. Currently the event specific data for

most events indicates the circuits to which the events apply in terms of a 32-

bit cic_mask with bits set to indicate the affected circuits within the circuit
group.

Note For reset indications, a 32-bit cic_mask is used but only the affected circuit within

the circuit group is indicated e.g. if a number of circuits are reset a maintenance

event indication message will be sent for each of the circuits reset.