19 maintenance event indication, Parameters, Maintenance event indication – Welltech Dialogic SS7 Protocols ISUP User Manual
Page 158: Ction
Section 8 Non-Primitive Interface
158
8.19
Maintenance Event Indication
This message is issued by the ISUP module to notify system maintenance of
various protocol events in accordance with ITU-T Q.764.
Message Header
structure
MSG
type
ISP_MSG_MAINT_IND (0x070a)
id
gid
src
ISUP module ID
dst
Maintenance module ID
rsp_req
0x00
hclass
0x00
status
Maintenance event code (see below)
err_info
Time-stamp
len
0, 1, 2 or 4
Parameter Area
parameters
offset 0, size Len
Event specific data
Parameters
gid
The group identifier for the Circuit Group.
Each indication may contain further Event Specific Data relating to the
event, this consists of 0, 1, 2 or 4 bytes of additional data which is contained
in the parameter area of the message. Currently the event specific data for
most events indicates the circuits to which the events apply in terms of a 32-
bit cic_mask with bits set to indicate the affected circuits within the circuit
group.
Note For reset indications, a 32-bit cic_mask is used but only the affected circuit within
the circuit group is indicated e.g. if a number of circuits are reset a maintenance
event indication message will be sent for each of the circuits reset.