Section 8 Non-Primitive Interface

136

cic_msb

This field contains the two most significant bytes of the base_cic of the first

circuit of the group when the group is using BICC variant.

8.3

Configure Timers Request

This message is used to configure the timer values for all of the ISUP protocol

timers. It is an optional message and need not be issued if the internal

default timer values are acceptable. The message may be issued at any time

after the initial per-module configuration message has been sent to the ISUP
module. Timer values will take effect the next time the timer is started.

The timer resolution for all protocol timers is either in units of num_tscan

system ticks or (in the case of T29 and T30) individual system ticks. Usually
the system tick is set to 100ms and num_tscan (in the per-module

configuration message) is set to 10 giving timer units of 1 second and 100ms

respectively.

The maximum timer value is 512 seconds.

The ID field is used to select the timer table to be configured. Up to four

timer tables can be supported.

Note The signaling point timers always use table 0.

Message Header

structure

MSG

type:

ISP_MSG_CNF_TIM (0x7702)

id

tim_tab_id

src

Originating module ID

dst

ISUP module ID

rsp_req

Sending layer’s bit set if confirmation required

hclass

0x00

status

0x00

err_info

0x00

len

0, 80, or 128 (see below)