beautypg.com

A.7 china isup, China isup – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 178

background image

Appendix A: ISUP National Variants

178

* Refer to

Section

6.5 on page 26

and

Section

6.6 on page 54

for details.

Parameters

When this variant is selected, the following French ISUP specific parameters

may be used:

Parameter Value

French ISUP

API

Length

Parameter Name

Hex

Dec

Hex

Dec

Mandatory/

Optional

Parameter

Min

Max

Message

used

Comments

Called directory
number [Numéro
d’annuaire du
demandé]

0x7d 125 0x1ed 493 Optional

2

18 IAM

Charge unit number
[Nombre d’unités de
taxation]

0xc3 195 0xff* 255* Mandatory 1

1

ITX

Maps

to

number of
metering
pulses
parameter
(API).

Message number
[Nombre de
messages]

0xc2 194 0xd7 215 Mandatory 1

1

ITX

* Refer to

Section

6.7 on page 80

for details.

A.7 China

ISUP

China ISUP Specification: YDN 038 (1997)

Configuration and options

In order to use this feature, ISPGVAR_CHN must be set in the ‘variant’ field in

the

Configure Circuit Group Request

message (see

Section

)

8.2 on page 126

.

For China ISUP, set the circuit group options as recommended for the ‘ITU’

variant (refer to

Appendix D: ISUP Configuration Option Settings on page

193

). In addition to these recommended option settings, the ISPF_24PC

module option (bit 8 in the ‘options’ field) and the ISPXGOP_24PC circuit

group option (bit 14 in the ‘extended options’ field) must also be set. The

ISPX1GOP_CCL circuit group configuration option (bit 8 in the ‘more extended
options’ field) applicable only to China ISUP, may optionally be set to enable

either a Calling Party Clearing Indication or a Release Indication to be sent to

the user application.