8.24 Heartbeat

Request/Indication

This message is issued by the ISUP module to determine the status of the

user application for instance whether it is in service and can also be sent, by

the user application, to request a new heartbeat message from the ISUP
module.

Message Header

structure

MSG

type

CAL_MSG_HEARTBEAT (0x7718)

T

id

0

1. ISUP module ID

src

2. User Application module ID

1. User Application module ID

dst

2. ISUP module ID

rsp_req

0x00

hclass

0x00

status

0x00

err_info

0x00

len

64

Parameter Area

offset 0, size 2:

user instance id

offset 2, size 2:

state

offset 4, size 2:

flags

parameters

offset 6, size 58:

reserved for future use - set to zero

Parameters

user instance id

The User ID.

state

The status of the user application.

Value

Meaning

Description

0 Unconfigured

No

circuit

groups have been configured.

1

Down

The user application is unavailable and out of service. The circuit
groups have been hardware blocked.

2

Up

The user application is available and in service.