24 heartbeat request/indication, Parameters, Heartbeat request/indication – Welltech Dialogic SS7 Protocols ISUP User Manual
Page 169
Dialogic
®
SS7 Protocols ISUP Programmer's Manual Issue 15
169
8.24 Heartbeat
Request/Indication
This message is issued by the ISUP module to determine the status of the
user application for instance whether it is in service and can also be sent, by
the user application, to request a new heartbeat message from the ISUP
module.
Message Header
structure
MSG
type
CAL_MSG_HEARTBEAT (0x7718)
T
id
0
1. ISUP module ID
src
2. User Application module ID
1. User Application module ID
dst
2. ISUP module ID
rsp_req
0x00
hclass
0x00
status
0x00
err_info
0x00
len
64
Parameter Area
offset 0, size 2:
user instance id
offset 2, size 2:
state
offset 4, size 2:
flags
parameters
offset 6, size 58:
reserved for future use - set to zero
Parameters
user instance id
The User ID.
state
The status of the user application.
Value
Meaning
Description
0 Unconfigured
No
circuit
groups have been configured.
1
Down
The user application is unavailable and out of service. The circuit
groups have been hardware blocked.
2
Up
The user application is available and in service.