Section 6 Interface to Application

102

The application must run all the timers associated with the continuity check
and perform the appropriate actions on expiry. For ITU ISUP, the timers are

as follows:

Timer

Value

Cause for initiation

Normal

termination

Action on expiry

T24 <2

seconds

When the Circuit
seized request (or the
Setup request for a call
where a continuity
check is to be
performed) is sent.

At the receipt
of backward
check tone.

Remove the transceiver, send
Continuity request with the
Continuity indicators set to
continuity check failed and
start T25 or T26 (as
appropriate). If a Setup
request had been sent, the
outgoing call should be
retried on another circuit.

T25 1-10

seconds

When continuity check
failure is detected after
sending a Setup
request.

-

Send Circuit seized request,
apply the transceiver, and
start T24.

T26 1-3

minutes

When continuity check
failure is detected after
sending a Circuit
seized request.

-

Send Circuit seized request,
apply the transceiver, and
start T24.

See

Section

:

8.3 Configure Timers Request on page 136

for details.

The following subsections show a number of different scenarios where a
continuity check is made on an outgoing circuit. In each case, the application

initiates the test by sending either a Setup request or a Circuit seized request

(depending on whether the continuity check is being performed during normal

call set up or as a continuity test call), applying a transceiver to the circuit to
generate the tone, and starting timer T24(waiting to send COT on receipt of

backward check tone). The Nature of connection indicators parameter in the

Circuit seized request or Setup request must have the Continuity check
indicator set to “continuity check required on this circuit”. If the application

detects that the backward check tone was received correctly, this indicates

that the continuity check was successful.