A.4 nortel rlt, A.4.1 nortel rlt (ansi), Nortel rlt – Welltech Dialogic SS7 Protocols ISUP User Manual
Page 174: A.4.1, Nortel rlt (ansi)
Appendix A: ISUP National Variants
174
Parameter Value
Japan (TTC)
ISUP
API
Length
Parameter Name
Hex
Dec
Hex
Dec
Mandatory/
Optional
Parameter
Min
Max
Message
used
Comments
National
redirection reason
0xf4 244 0xf4 244 Optional
1 1
IAM,
REL
Network function
type
0xfe 254 0x1fe 510 Optional
2 254 ACM,
CON,
IAM
Mobile
communication
call number
0x47 247 0xf0 240 Optional
7
7
ACM,
CPG,
IAM
Mobile
communication
end information
transfer
0xf8 248 0xe2 226 Optional
1 255 ACM,
ANM,
CPG, IAM,
REL, SUS
PHS terminal
identification
number
0xf6 246 0xe0 224 Optional
2 18 IAM
Redirecting
number*
0x0b 11 0x0b 11 Optional
2
18 IAM
Subscriber
number
0xf9 249 0xdf 223 Optional
2 17 IAM
* Refer to
Section
A.4 Nortel
RLT
A.4.1
Nortel RLT (ANSI)
Configuration and options
In order to use this feature, ISPGVAR_ANSI_RLT in the ‘variant’ field must
be set in the
Configure Circuit Group Request
message (see
Section
.
For Nortel RLT(ANSI) ISUP, set the circuit group options as recommended for
the ‘ANSI’ variant (refer to
Appendix D: ISUP Configuration Option Settings
). In addition to these recommended option settings, the
ISPX1GOP_USR_SVC_PRV circuit group option (bit 3 in the ‘more extended
options’) must also be set.
Parameters
When this variant is selected, the following Nortel RLT(ANSI) ISUP specific
parameters may be used: