beautypg.com

3 cause indicators, Cause indicators, Figure 4 – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 87: Format of the cause indicators parameter, Table 2, Section, 3 on, Of this m

background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

87

6.7.3 Cause

Indicators

The format of the cause indicators parameter is defined in ITU-T Q.763

Section 3.12. Due to the importance of the parameter it is also shown in the
following figure:

Figure 4.

Format of the Cause Indicators Parameter

8 7 6 5 4 3 2 1

Name = 00010010 (18)

Length = 2 - 255

1 Ext.

Coding

standard

Spare

Location

2 Ext.

Cause

value

3

First octet of diagnostics (if any)

:

n

Last octet of diagnostics (if any)

The following table lists the release cause values that are used in the Release

indication sent to the application when call processing timers expire.

Table 2.

Release Cause Values used in the Release indication sent to the

Application when Call Processing Timers Expire

Timer

Cause

Timer

Description

Value

Description

T2

Waiting for RES after (user) SUS is
received

102

Recovery on timer expiry

T3

Started on receipt of overload message

31

Normal, unspecified

T6

Waiting for RES after (network) SUS is
received

102

Recovery on timer expiry

T7

Waiting for ACM

31

Normal, unspecified

T8

Waiting for COT

41

Temporary failure

T9

Waiting for ANM

19

No answer from user (user
alerted)

T35

Waiting for ST digit

28

Address incomplete

T38

Waiting for RES after (network) SUS is
received in an international exchange

-

timer not supported