Section 8 Non-Primitive Interface
156
• CGSC_REQ- Circuit Group Supervision Control Request
• OVLD_REQ- Overload Request
non_prim_mask
The non-primitive trace mask. This is a 32-bit value with bits set to 1 to
cause a trace message to be sent to the system trace module when ISUP
receives the associated non-primitive message.
31 30 29 28 27 26 25 24
0 0 0 0 0 0 0 0
23
22 21 20 19 18 17 16
0
0 0 0 0 0 0 CONFIG
15 14 13 12
11 10
9
8
HRTBT
R GRPID
R DATA
CNG GRP
CUST
PARAM
SET
CUSTVAR
MGT EV
IND
SW
EVT
7 6 5
4 3 2 1
0
MT EVT
SSW
MSK
SMT
MSK
R STATUS
END
GRP
CNF
GRP
CNF
TIM
0
(reserved)
• CNF_TIM – Timer Configuration Message
• CNF_GRP – Circuit Group Configuration Message
• END_GRP – End Circuit Group Request
• R_STATUS – Read Circuit Group Status Request
• SMT_MSK – Send Maintenance Event Mask Request
• SSW_MSK – Send Software Event Mask Request
• MT_EVT – Maintenance Event Indication
• SW_EVT – Software Event Indication
• MGT_EV – Management Event Indication
• SET_CUSTVAR – Set Custom Variant Message
• CUSTPARAM – Custom Variant Parameter Message
• CNG_GRP – Change Circuit Group Configuration Request
• R_DATA – Read Circuit Group Data Request
• R_GRPID – Read Circuit Group Identity Request
• HRTBT - Heartbeat Request/Indication
• CONFIG - Configure Request