119
ISUP Response
method
By returning the message to the sender
type
0x370d
SUCCESS
ISP_BAD_ID
status
ISP_BAD_PARAM
Parameters
overload_level
This is the overload level that the application wishes to indicate to the remote
signaling point. Permitted values are listed in the following table:
Value
Meaning
0 Overload
condition
no longer exists.
1
Lower overload level exceeded.
2
Upper overload level exceeded.
7.7
Remote Point Code Status Indication
This primitive is used by the ISUP module to inform the user of the
availability and congestion status of a remote signaling point.
Primitive Indication From ISUP
type
ISP_MSG_STATUS (0x070e)
id
0
src
ISUP module ID
dst
Management module ID
rsp_req
0x00
hclass
0x00
0x01 = Remote user unavailable
status
0x02 = Congestion
err_info
0x00
len
6
offset 0, size 4
affected point code
parameters
offset 4, size 2
congestion_status (only applicable for remote congestion,
otherwise set to zero)