beautypg.com

Parameters, 7 remote point code status indication, Remote point code status indication – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 119

background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

119

ISUP Response

method

By returning the message to the sender

type

0x370d

SUCCESS

ISP_BAD_ID

status

ISP_BAD_PARAM

Parameters

overload_level

This is the overload level that the application wishes to indicate to the remote
signaling point. Permitted values are listed in the following table:

Value

Meaning

0 Overload

condition

no longer exists.

1

Lower overload level exceeded.

2

Upper overload level exceeded.

7.7

Remote Point Code Status Indication

This primitive is used by the ISUP module to inform the user of the
availability and congestion status of a remote signaling point.

Primitive Indication From ISUP

type

ISP_MSG_STATUS (0x070e)

id

0

src

ISUP module ID

dst

Management module ID

rsp_req

0x00

hclass

0x00

0x01 = Remote user unavailable

status

0x02 = Congestion

err_info

0x00

len

6

offset 0, size 4

affected point code

parameters

offset 4, size 2

congestion_status (only applicable for remote congestion,
otherwise set to zero)