beautypg.com

Welltech Dialogic SS7 Protocols ISUP User Manual

Page 129

background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

129

Bit Number

Mnemonic

Description

11

ISPGOP_COM

If set to 1, the user application is permitted to send
a Call Offering Message (COM) to the network.
This option is intended for use only in the Italian
national network and should otherwise be set to
zero.

12

ISPGOP_T35

If set to 1, protocol timer T35 will be enabled. If set
to zero, timer T35 will be disabled. T35 is started
on receipt of an IAM from the network and restarted
on receipt of any SAM messages until an ST digit is
received. If the timer expires, the call is
automatically cleared.

13

Reserved

Reserved for future use and must be set to zero.

14

ISPGOP_TCCR_CTRL

If set to 1, the ISUP module will run T104 which is
used whilst awaiting the LPA message after having
sent CCR. On expiry, the circuit is reset. If set to
zero, T104 will not run and the LPA message will
not be handled.

15

Reserved

Reserved for future use – set to zero.

ext_options

The extended options field allows various run-time options as shown in the

following table to be selected for the circuits in the circuit group.

Bit Number

Mnemonic

Description

0

ISPXGOP_BLK_767

This bit selects the abnormal circuit group
blocking procedures to be used and should be
set as follows:

• 0 - Q.764 (Blue Book) operation
• 1 - Q.767, Q.764 (03/93) and ANSI T1.113

operation

1

ISPXGOP_UBK_MH

If set to 1, a received circuit group unblocking
message will remove both the remote
Maintenance and Hardware blocking conditions
regardless of the value of the received circuit
group supervision message type indicator.
Otherwise, the type of a received Unblocking
message must match that of the previously
received Blocking message to remove the
remote blocking condition.

2

ISPXGOP_RPT_CGSM

If set to 1, the ISUP module will repeat CGB
messages for each circuit group blocking
operation and repeat GRS for each circuit group
reset operation. If set to zero, only one message
will be issued for each operation.

Note: this option should be set for ANSI based
operations.

3

ISPXGOP_UMSG_CFN

If set to 1, when the module receives an
unrecognized protocol message it will issue a
‘Confusion’ (CFN) message and will recognize
receipt of a CFN message.