beautypg.com

8 read ram request, 9 read circuit group request, Read ram request – Welltech Dialogic SS7 Protocols ISUP User Manual

Page 145: Read circuit group request

background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

145

8.8 Read

RAM

Request

This message is provided solely for diagnostic purposes to request the

address of the ISUP modules internal ram structure for diagnostic purposes.

Read Request to ISUP

structure

MSG

type

ISP_MSG_R_RAM (0x6704)

id

0

src

Originating module ID

dst

ISUP module ID

rsp_req

Sending layer's bit set

hclass

0x00

status

0x00

err_info

0x00

len

4

parameters

offset 0, size 4:

RAM address written by ISUP in response message.

ISUP Response

method

By sending a MSG

type

0x2704

status

SUCCESS

8.9

Read Circuit Group Request

This message is provided solely for diagnostic purposes to request the
address of the given circuit group structure in the ISUP modules internal ram

structure for diagnostic purposes.

Read Request to ISUP

structure

MSG

type

ISP_MSG_R_GRP (0x6705)

id

gid (Circuit Group Identifier)

src

originating module ID

dst

ISUP module ID

rsp_req

sending layer's bit set

hclass

0x00

status

0x00

err_info

0x00

len

4

parameters

offset 0, size 4:

Address of circuit group structure written by
ISUP in response message.