Welltech Dialogic SS7 Protocols ISUP User Manual
Page 81
![background image](https://www.manualsdir.com/files/809462/content/doc081.png)
Dialogic
®
SS7 Protocols ISUP Programmer's Manual Issue 15
81
Value
Length
Parameter Name
Hex
Dec
Definition/Reference
Min
Max
Notes
Called directory number
0x1ed
493
Q.1902.3 section 6.15
2
18
-
Called party number
0x04
4
See
of this manual
1 18 5
Called IN number
0x6f
111
Q.763 Section 3.73
(09/97)
2 18 -
Calling geodetic location
0x81
129
Q.1902.3 section 6.15
8
255
1
Calling party geodetic
velocity information
0x83
131
Q.1902.3 section 6.19
4
255
1
Calling party number
0x0a
10
See
of this manual
2 18 -
Calling party’s category
0x09
9
Q.763 Section 3.11
1
1
-
Carrier identification
0xc5
197
T1.113 Section 3.8A
3
3
1
Carrier selection
information
0xee
238
T1.113 Section 3.8B &
Q.1902.3 section 6.22
1 1 1
Cause indicators
0x12
18
See
of this manual
2 255
-
CCNR possible indicator
122
0x7a
Q.1902.3 section 6.24
1
1
-
CCSS
0x4b
75
Q.763 Section 3.63
(09/97)
1 1 1
Charge number
0xeb
235
T1.113 Section 3.10
1
13
1
Charged party
identification
0x71
113
Q.763 Section 3.75
(09/97)
1 255
1
Circuit assignment map
0x25
37
T1.113 Section 3.10B
4
4
1
Circuit group
characteristic indicator
0xe5
229
T1.113 Section 3.10A
1
1
1
Circuit group supervision
message type
0x15
21
Q.763 Section 3.13
1
1
3
Circuit identification
name
0xe8
232
T1.113 Section 3.11A
26
26
1
Circuit state indicator
0x26
38
Q.763 Section 3.14
2
32
3
Circuit validation
response indicator
0xe6
230
T1.113 Section 3.11C
1
1
1
Closed user group
interlock code
0x1a
26
Q.763 Section 3.15
4
4
1
Coding decoding
processing
0xa5
165
Q.1902.3 section 6.31
1
255
1
Collect call request
0x79
121
Q.763 Section 3.81
(09/97)
1 1 1
Conference treatment
indicators
0x72
114
Q.763 Section 3
(09/97)
1 1
Connected number
0x21
33
Q.763 Section 3.16
2
13
1
Connection request
0x0d
13
Q.763 Section 3.17
5
7
1