beautypg.com

Welltech Dialogic SS7 Protocols ISUP User Manual

Page 139

background image

Dialogic

®

SS7 Protocols ISUP Programmer's Manual Issue 15

139

Timer

ISUP Default

(seconds)

BICC Default

(seconds)

Description

before sending ACM

t11

not implemented

not implemented

N/A

t12

10

0

Waiting for BLA

t13

60

0

Delay to alert maintenance on failure to
receive BLA

t14

10

0

Waiting for UBA

t15

60

0

Delay to alert maintenance on failure to
receive UBA

t16

10

10

Waiting for RLC after sending RSC not
due to T5 expiry

t17

60

60

Delay to alert maintenance on failure to
receive acknowledgement of RSC.

T18

10 10 Waiting

for

GBA

t19

60

60

Delay to alert maintenance on failure to
receive GBA

t20

10 10 Waiting

for

GUA

t21

60

60

Delay to alert maintenance on failure to
receive GUA

t22

10 10 Waiting

for

GRA

t23

60

60

Delay to alert maintenance on failure to
receive GRA

t24

2

0

Waiting for sending COT on receipt of
backward check tone

t25

5

0

Waiting for sending CCR and repeat
continuity check

t26

120

0

Waiting for sending CCR on subsequent
cot failure

t27

240

0

Waiting for continuity check request on
receipt of cot failure indication

t28

10 10 Waiting

for

CQR

t29

0.5

0.5

Waiting for new congestion indication

t30

8

8

Delay to restore traffic by one step on
receipt of congestion indication

t31

not implemented

not implemented

N/A

t32

not implemented

not implemented

N/A

t33

14

14

Waiting for INF after sending INR

t34

3

3

Waiting for segmentation message

t35

20

20

Waiting for ST digit of for the minimum of
digits

t36

13

0

Wait for REL after receiving CCR (Note:
ANSI T1.113-1995 refers to this timer as
T34)

t37

not implemented

not implemented

N/A