60
Installation & Setup Guide
Use Marker Pulse
When enabled, the absolute home position will be assigned at the instant the marker pulse is
detected. It is recommended that the Marker Pulse be used for optimal homing repeatability.
Use Software Travel Limits
The control is capable of running with software Overtravel limit switches. These switches act just like
the hardware switches, but require no additional hardware.
Software Overtravels are only practical in cutting machines when Absolute RS-274D programming is
used.
Maximum Travel Limit
If Software Overtravels are enabled, the user is prompted for the maximum travel of the cutting
machine.
Minimum Travel Limit
If Software Overtravels are enabled, the user is prompted for the minimum travel of the cutting
machine.