Hypertherm HTA Rev 6.00 Install Guide User Manual
Page 228
216
Installation & Setup Guide
I/O Configuration Type “V”
Due to the ability to select the Analog Input being used for a selected THC and the ability to configure
the Input and Output locations, no exact or standard Pinout for the THC connections is available.
Connections would be made by selecting the Analog Input for the desired THC and connecting the
Analog signals from the Voltage Divider Card. In much the same manner, the required Nozzle
Contact Sense, Nozzle Contact Enable and Hold Ignition I/O points would be selected and connected
to the corresponding appropriate pins on the Voltage Divider Card.
Description
Divider J2 Pin #
Analog +
J2 - 6
Analog –
J2 - 7
Nozzle Contact Sense +
J2 - 2
Nozzle Contact Sense –
J2 - 3
Nozzle Contact Enable +
J2 - 4
Nozzle Contact Enable –
J2 - 5
Hold Ignition +
N/A ( direct to power supply )*
Hold Ignition –
N/A ( direct to power supply )*
Shield
J2 - 8
* Note: It is recommended that the Hold Ignition input be wired to the Power Supply through an
external relay for noise immunity. Please refer to Instructions from the supply manufacturer for
details on connection to the Hold Ignition Input.