beautypg.com

Hypertherm HTA Rev 6.00 Install Guide User Manual

Page 133

background image

Appendix B: Mariner™ & Voyager II™

121

HD3070

®

Auto Gas I/O

The Interface to the HD3070

®

Auto Gas console is made through of Single Ended and BCD ( Binary

Coded Decimal ) inputs. The BCD style of interface allows for exact settings by use of multiple
inputs being active at any time. The active BCD input values are summed together to obtain the
exact set point.

These I/O points are wired in the same fashion as our other Single Ended I/O points. The following
I/O points are supplied for use of the HD3070

®

Auto Gas Console


Inputs
Gas Control Read Complete
Gas Control Error

Outputs
Gas Control Write

Remote Test Operate

Remote Test Preflow

Remote Air Plasma

Remote H35/ N2 Plasma

Remote O2 Plasma

Gas Flow Set 1-100 ( BCD )

Valve Select 1-8 ( BCD )


Cut Chart Setup through part program codes is supported. Refer to Part Programming section of the
Installation Guide.

This manual is related to the following products: