Transverse 2 axis, Tilt rotator part codes – Hypertherm HTA Rev 6.00 Install Guide User Manual
Page 129
Appendix B: Mariner™ & Voyager II™
117
Transverse 2 Axis
Minimum Torch Spacing
This value set a minimum distance allowed between Transverse 1 and Transverse 2 axes.
Mirrored Marker Offsets
This feature allows preset tool offsets to be performed as mirrored motion for the Transverse 2 axis.
Tilt Rotator Part Codes
Kerf Table
Code Description
G59 D1-200Xvalue Sets kerf table variable from 1-200
G41 D1-200
Enables Left Kerf using a Kerf Table variable
G42 D1-200
Enables Right Kerf using a Kerf Table variable
G43 D1-200
Changes current kerf value via Kerf Table using previously set Left or Right
kerf
Tilt/Rotator
Code Description
G00 Avalue
Sets Tilt angle – A is the angle value in degrees
G00 Xvalue Yvalue Avalue Performs Linear Interpolation of Tilt angle along line segment.
G00 Avalue Fvalue
Sets Tilt angle – Angle value in degrees with a speed command in RPM
M28
Disables Follower
M29
Enables Follower
M90
Preparatory Cmd - Aligns Rotator to Tangent angle of next cut segment
M75
A axis/Tilt Goto Home Cmd - Rapid Index