beautypg.com

Hypertherm HTA Rev 6.00 Install Guide User Manual

Page 152

background image

140

Installation & Setup Guide

EIA CODE

DESCRIPTION

MAPPED TO

G45

Lead In to Kerfed Part

G01, G02, or G03

G70

Select

English

Units

G20

G71

Select

Metric

Units

G21

G98

End of Subroutine Loop

M41


M03

Cutting Device On/Off

M07 ( Oxy Fuel ) or M08 as appropriate

M04

Cutting

Device

On

M07

M05

Cutting Device Off

M08 ( Oxy Fuel )

M06

Cutting

Device

Off

M08

M06

Enable

Marker

2 M13

M07

Disable Marker 1 or 2

M10 or M14 as appropriate

M08

Enable

Marker

1 M09

M09

Disable Marker 1 or 2

M10 or M14 as appropriate

M10

Enable

Marker

2 M13

M14

Height

Sensor

Disable

M50

M15

Height

Sensor

Enable

M51

M20

Cutting Device On/Off

M07 or M08 as appropriate ( Plasma )

M21

Cutting Device On/Off

M07 or M08 as appropriate ( Plasma )

M20

Output

9

On

O9

S1

M21

Output

9

Off

O9

S0

M22

Output

12

On

O12

S1

M23

Output

12

Off

O12

S0

M24

Wait for Input 7 On

W7 S1

M25

Wait for Input 8 On

W8 S1

M25

CBH

Enable

M29

M26

Wait for Input 7 Off

W7 S0

M26

CBH

Disable

M28

M27

Wait for Input 8 Off

W8 S0

M67,

M02

Kerf

Left G41

M68,

M03

Kerf

Right

G42

M69, M04

Kerf Off

G40

M65, M70

Cutting Device On

M07

M66, M71, M73

Cutting Device Off

M08

M70

Marker

Offset

1

Off

M12

M71

Marker

Offset

1

On

M11

M70T01

Marker Offset 1 Off

M12

M71T01

Marker Offset 1 On

M11

M70T02

Marker Offset 2 Off

M72

M71T02

Marker Offset 2 On

M73

M70T03

Marker Offset 3 Off

M274

M71T03

Marker Offset 3 On

M275

M70T04

Marker Offset 4 Off

M276

M71T04

Marker Offset 4 On

M277

M70T05

Marker Offset 5 Off

M278

M71T05

Marker Offset 5 On

M279

M70T06

Marker Offset 6 Off

M280

M71T06

Marker Offset 6 On

M281

M70T07

Marker Offset 7 Off

M282

M71T07

Marker Offset 7 On

M283

M70T08

Marker Offset 8 Off

M284

M71T08

Marker Offset 8 On

M285

M98

End

Comment

)