140
Installation & Setup Guide
EIA CODE
DESCRIPTION
MAPPED TO
G45
Lead In to Kerfed Part
G01, G02, or G03
G70
Select
English
Units
G20
G71
Select
Metric
Units
G21
G98
End of Subroutine Loop
M41
M03
Cutting Device On/Off
M07 ( Oxy Fuel ) or M08 as appropriate
M04
Cutting
Device
On
M07
M05
Cutting Device Off
M08 ( Oxy Fuel )
M06
Cutting
Device
Off
M08
M06
Enable
Marker
2 M13
M07
Disable Marker 1 or 2
M10 or M14 as appropriate
M08
Enable
Marker
1 M09
M09
Disable Marker 1 or 2
M10 or M14 as appropriate
M10
Enable
Marker
2 M13
M14
Height
Sensor
Disable
M50
M15
Height
Sensor
Enable
M51
M20
Cutting Device On/Off
M07 or M08 as appropriate ( Plasma )
M21
Cutting Device On/Off
M07 or M08 as appropriate ( Plasma )
M20
Output
9
On
O9
S1
M21
Output
9
Off
O9
S0
M22
Output
12
On
O12
S1
M23
Output
12
Off
O12
S0
M24
Wait for Input 7 On
W7 S1
M25
Wait for Input 8 On
W8 S1
M25
CBH
Enable
M29
M26
Wait for Input 7 Off
W7 S0
M26
CBH
Disable
M28
M27
Wait for Input 8 Off
W8 S0
M67,
M02
Kerf
Left G41
M68,
M03
Kerf
Right
G42
M69, M04
Kerf Off
G40
M65, M70
Cutting Device On
M07
M66, M71, M73
Cutting Device Off
M08
M70
Marker
Offset
1
Off
M12
M71
Marker
Offset
1
On
M11
M70T01
Marker Offset 1 Off
M12
M71T01
Marker Offset 1 On
M11
M70T02
Marker Offset 2 Off
M72
M71T02
Marker Offset 2 On
M73
M70T03
Marker Offset 3 Off
M274
M71T03
Marker Offset 3 On
M275
M70T04
Marker Offset 4 Off
M276
M71T04
Marker Offset 4 On
M277
M70T05
Marker Offset 5 Off
M278
M71T05
Marker Offset 5 On
M279
M70T06
Marker Offset 6 Off
M280
M71T06
Marker Offset 6 On
M281
M70T07
Marker Offset 7 Off
M282
M71T07
Marker Offset 7 On
M283
M70T08
Marker Offset 8 Off
M284
M71T08
Marker Offset 8 On
M285
M98
End
Comment
)