Hypertherm HTA Rev 6.00 Install Guide User Manual
Page 156

144
Installation & Setup Guide
ESSI CODE
DESCRIPTION
MAPPED TO EIA
11+7
Marker
Offset
7
On
M283
12+7
Marker
Offset
7
Off
M282
11+8
Marker
Offset
8
On
M285
12+8
Marker Offset 8 Off
M284
13
Enable
Marker
2 M13
14
Disable
Marker
2 M14
15
Marker
Offset
2
On
M73
16
Marker
Offset
2
Off
M72
21
No Mirror, No Rotate
G99 X1 Y0 I0 J0
22
Mirror Y, No Rotate
G99 X1 Y0 I0 J1
23
Mirror X and Y
G99 X1 Y0 I1 J1
24
Mirror X, No Rotate
G99 X1 Y0 I1 J0
25
Mirror X/Y on -45 Deg
G99 X1 Y270 I1 J0
26
Rotate 90 Deg CCW
G99 X1 Y90 I0 J0
27
Mirror X/Y on +45 Deg
G99 X1 Y270 I0 J1
28
Rotate 90 Deg CW
G99 X1 Y270 I0 J0
29
Enable Left Kerf Comp
G41
30
Enable Right Kerf Comp
G42
38
Disable
Kerf
G40
39+value Machine
Speed
Fvalue
40+value Programmable
Kerf
G43
Xvalue
41
Preset
Dwell
G04
41+value
Program Dwell in mSec
G04 Xvalue
45
Ht
Sensor
Enable/Lower M53
46
Ht
Sensor
Disable/Raise M52
47
Ht
Sensor
Enable
M51
48
Ht
Sensor
Disable
M50
51
CBH
Enable
M29
52
CBH
Disable
M28
53
Cutting
Device
On
M07
54
Cutting
Device
Off
M08
63
Reset
Functions M31
64
End
Program
M02
65
End of Program/ Reload
M65
67
Ht
Sensor
Disable
M50
68
Ht
Sensor
Enable
M51
70
Select English Units (in)
G20
71
Select
Metric
Units
(mm) G21
79+1
Go To Home Position 1
M79 T1
79+2
Go To Home Position 2
M79 T2
79+3
Go To Home Position 3
M79 T3
79+4
Go To Home Position 4
M79 T4
81
Incremental
Mode
G91
82
Absolute
Mode
G90
83
Set
Axis
Presets G92
90
End of Program
M02
97
Program Repeat Pointer
G97
97+value Subroutine
Loop M40
Xvalue
98
Repeat at 97, Subroutine loop G97, G98 or M41 as appropriate
or start of program if no 97
99
End of Program
M02