Hypertherm HTA Rev 6.00 Install Guide User Manual
Page 199
Appendix E: Voyager™ II Machine Interface
187
Single Ended I/O Pinout
The Single Ended I/O offers 32 outputs which are rated at 24VDC for up to 1-amp loads and 32
inputs rated for 24VDC as standard
I/O Connector J5
Pin Description Default
I/O
Description
1 Input
1
Spare
2
Input 2
Z Home Switch
3
Input 3
Program Inhibit
4
Input 4
Cut/ Mark Sense 1
5
Input 5
Cut/ Mark Sense 2
6
Input 6
Remote Pause
7
Input 7
Drive Disabled
8 Input
8
Spare
9
Input 9
X Home Switch
10
Input 10
X+ Overtravel
11
Input 11
Y Home Switch
12
Input 12
Y+ Overtravel
13
Input 13
Plasma I Select
14
Input 14
Plasma 2 Select
15
Input 15
Marker 1 Select
16
Input 16
Marker 2 Select
17 +24
VDC
N/A
18 +24
VDC
N/A
19 Chassis
Ground
N/A
20
Output 1
Torch Up
21
Output 2
Torch Down
22 Output
3
Ignition
23
Output 4
Torch Height Disable
24
Output 5
Hold Ignition
25 Output
6
Marker
26
Output 7
Cut Control
27
Output 8
Plasma 1 Enable
28
Output 9
Plasma 2 Enable
29
Output 10
High Preheat Control
30
Output 11
Low Preheat Control
31
Output 12
Marker 1 Enable
32
Output 13
Marker 2 Enable
33
Output 14
Gas Control Write
34
Output 15
Remote Test Operate
35
Output 16
Remote Test Preflow
36
+24 VDC Common
N/A
37
+24 VDC Common
N/A
Mating Connector
Connector: 37C D-Sub Amp # 205210-3 or equivalent
Backshell: Amp #748676-4 or equivalent
Pins: Amp #5-66507-9 ( 24-28 AWG ) or equivalent