beautypg.com

Hypertherm HTA Rev 6.00 Install Guide User Manual

Page 199

background image

Appendix E: Voyager™ II Machine Interface

187


Single Ended I/O Pinout
The Single Ended I/O offers 32 outputs which are rated at 24VDC for up to 1-amp loads and 32
inputs rated for 24VDC as standard

I/O Connector J5

Pin Description Default

I/O

Description

1 Input

1

Spare

2

Input 2

Z Home Switch

3

Input 3

Program Inhibit

4

Input 4

Cut/ Mark Sense 1

5

Input 5

Cut/ Mark Sense 2

6

Input 6

Remote Pause

7

Input 7

Drive Disabled

8 Input

8

Spare

9

Input 9

X Home Switch

10

Input 10

X+ Overtravel

11

Input 11

Y Home Switch

12

Input 12

Y+ Overtravel

13

Input 13

Plasma I Select

14

Input 14

Plasma 2 Select

15

Input 15

Marker 1 Select

16

Input 16

Marker 2 Select

17 +24

VDC

N/A

18 +24

VDC

N/A

19 Chassis

Ground

N/A

20

Output 1

Torch Up

21

Output 2

Torch Down

22 Output

3

Ignition

23

Output 4

Torch Height Disable

24

Output 5

Hold Ignition

25 Output

6

Marker

26

Output 7

Cut Control

27

Output 8

Plasma 1 Enable

28

Output 9

Plasma 2 Enable

29

Output 10

High Preheat Control

30

Output 11

Low Preheat Control

31

Output 12

Marker 1 Enable

32

Output 13

Marker 2 Enable

33

Output 14

Gas Control Write

34

Output 15

Remote Test Operate

35

Output 16

Remote Test Preflow

36

+24 VDC Common

N/A

37

+24 VDC Common

N/A


Mating Connector
Connector: 37C D-Sub Amp # 205210-3 or equivalent
Backshell: Amp #748676-4 or equivalent
Pins: Amp #5-66507-9 ( 24-28 AWG ) or equivalent

This manual is related to the following products: