Section 4: Password Setups
49
Digital Beam
The Digital Beam Output is used exclusively with the Laser cut logic
and is used to activate the Digital Beam.
Laser Start
The Laser Start Output is used exclusively with the Laser cut logic
and is used to activate the Laser System.
Abrasive Control
The Abrasive Control Output is used exclusively with Water Jet cut
logic and activates the abrasive control adding abrasive to the cut
stream while cutting or for charging the abrasive prior to cutting.
Plasma Enables
These outputs are used for external logic. The appropriate Output(s)
is on during plasma cutting, based on the Plasma Select Inputs.
Marker Enables
These outputs are used for external logic. The appropriate Output(s)
is on during marking, based on the Marker Select Inputs.
Nozzle Contact Enable
The Nozzle Contact Enable Output is active during Sensor™ THC
Initial Height Sense. This input is tied back to the control through the
external Voltage Divider Card. This output may also be used to
switch an external drive system to low output mode (if equipped )
during IHS for stall force plate sensing.
Hold Ignition
The Hold Ignition Output is part of the Sensor™ THC operation and
used to hold ignition of the external Plasma Supply. This output may
be tied back to the control through the external Voltage Divider Card
or direct to the Power Supply depending on configuration.
Gas Flow Set 1 – 100
The Gas flow Set Output is used as part of the HD3070
®
Automatic
Gas Console communications (BCD) to set Gas Flow rates.
Valve Select 1 – 8
The Valve Select Output is used as part of the HD3070
®
Automatic
Gas Console communications to select the appropriate valves for
operation.
Gas Control Write
The Gas Control Write Output is used as part of the HD3070
®
Automatic Gas Console communications to configure the unit for
operation.
Remote Test Operate
The Remote Test Operate Output is used as part of the HD3070
®
Automatic Gas Console communications to Initiate the Remote Test.
Remote Test Preflow
The Remote Test Preflow Output is used as part of the HD3070
®
Automatic Gas Console communications to test operation of Preflow
gases.
Remote Air Plasma
The Remote Air Plasma Output is used as part of the HD3070
®
Automatic Gas Console communications to signal the Air Plasma
Output.
Remote H35/ N2 Plasma
The Remote H35/N2 Plasma Output is used as part of the HD3070
®
Automatic Gas Console communications to signal the H35/N2
Output.
Remote O2 Plasma
The Remote O2 Plasma Output is used as part of the HD3070
®
Automatic Gas Console communications to signal the O2 Output.