I/o configuration type “m” ( double ended i/o ) – Hypertherm HTA Rev 6.00 Install Guide User Manual
Page 186

174
Installation & Setup Guide
I/O Configuration Type “M” ( Double Ended I/O )
The double ended I/O configuration of the control provides additional flexibility in connecting to
external devices. These I/O points allow the user to separate the control voltages for each I/O point.
Meaning, there is no common tie between each point as with the single ended I/O scheme. No power
is required to be brought into the control. Pins 34-37 are provided for the optional internal +24V
supply should the user want the power supply integrated into the control.
Double Ended I/O Pinout
The Single Ended I/O offers eight outputs which are rated at 24VDC for up to 1-amp loads and eight
inputs rated for 24VDC.
Pin I/O
Description
1
Input 1 +
Torch Up Sense
2
Input 1 -
Torch Up Sense
3
Input 2 +
Spare
4
Input 2 -
Spare
5
Input 3 +
Preheat Sense
6
Input 3 -
Preheat Sense
7
Input 4 +
Cut Sense
8
Input 4 -
Cut Sense
9
Input 5 +
Spare
10
Input 5 -
Spare
11
Input 6 +
Limit Switch
12
Input 6 -
Limit Switch
13
Input 7 +
Torch Down Sense
14
Input 7 -
Torch Down Sense
15
Input 8 +
Spare or Remote Pause
16
Input 8 -
Spare or Remote Pause
17
Output 1 +
Torch Up
18
Output 1 -
Torch Up
19
Output 2 +
Torch Down
20
Output 2 -
Torch Down
21
Output 3 +
Ignition Control
22
Output 3 -
Ignition Control
23
Output 4 +
Torch Height Disable/Dual Grid Control
24
Output 4 -
Torch Height Disable/Dual Grid Control
25
Output 5 +
CNC
26
Output 5 -
CNC
27
Output 6 +
Marker Enable or Beeper or Motion Indicator
28
Output 6 -
Marker Enable or Beeper or Motion Indicator
29
Output 7 +
Preheat Control
30
Output 7 -
Preheat Control
31
Output 8 +
Cut Control
32
Output 8 -
Cut Control
33
I/O Shield
Chassis Ground
34
+24 VDC
+I/O Power Supply
35
+24 VDC
+I/O Power Supply
36
24 V Common
I/O Power Supply Common
37
24 V Common
I/O Power Supply Common