Hypertherm HTA Rev 6.00 Install Guide User Manual
Page 221
Appendix H: Sensor™ THC
209
Sensor™ THC Part Program Support
Sensor™ THC offers the ability to configure THC setup parameters through part program codes.
The following parameters are available for use using EIA-274D G59 codes:
Arc Voltage
Pierce / Start Time
Pierce/ Start Height Factor
Cut / Mark Height
Setup is obtained using the following format.
Example:
G59 V601 Fvalue
Misc. G Code
Variable Identity
V600 = Plasma 1 Arc Voltage
V601 = Plasma 1 Pierce Time
V602 = Plasma 1 Pierce Height Factor
V603 = Plasma 1 Cut Height
V625 = Plasma 2 Arc Voltage
V626 = Plasma 2 Pierce Time
V627 = Plasma 2 Pierce Height Factor
V628 = Plasma 2 Cut Height
V650 = Marker 1 Arc Voltage
V651 = Marker 1 Start Time
V652 = Marker 1 Start Height Factor
V653 = Marker 1 Mark Height
V675 = Marker 2 Arc Voltage
V676 = Marker 2 Start Time
V677 = Marker 2 Start Height Factor
V678 = Marker 2 Mark Height
Variable Value
The selected value for the variable