Section 4: Password Setups

55

Plasma Start

This output is used to start the plasma system in plasma mode.



Plasma Height Disable

This output is used to disable the automatic torch height controller in
plasma mode. It is activated whenever the current axis position is
within the “Plasma Distance To Corner” or the “Plasma Distance
From Corner” parameters while cutting a part. It is also active
whenever the current cutting speed drops below the result of
(Programmed Cut Speed x (Plasma High/Lo Speed/100)).


Plate Marker No. 1

This output is used to activate a marking device. This output is
enabled by marking codes within the part program.


Plate Marker No. 2

This output is used to activate a marking device. This output is
enabled by marking codes within the part program.


CNC Tracer

This output is used to control a CNC relay. The CNC relay
determines whether the control, tracing system or joystick is
commanding the amplifiers. This output is deactivated whenever the
control is off, in Teach Trace mode or is disabled. Otherwise it is
always activated.


Bleed Off Gas

The Bleed Off Gas output is used by the Oxy fuel cut logic to send

an output to the Oxy torch to purge gases at the end of a cut.
This Output is on for the duration of the Bleed Off Time selected

in setups.


Aux Tool Select

The Auxiliary Tool Select Output is used with the type “B” I/O

configuration to allow the control to activate multiple tools on the
cutting table. The output is activated through use of Marking

codes (EIA M10 / M11) within the part program.


Drive Enable

The Drive Enable Output is used to enable the Drives during

normal functions and to disable the Drives during fault

conditions.



Drive Enables
This setup parameter allows the user to select how the control responds to drive faults. If the setting
is Series, then all axes must complete their individual fault ramp times before the drives are disabled.
If the setting is independent, each drive is disabled immediately as soon as its axis fault ramp time is
finished.

Initial Feedback Delay
This feature allows the initial feedback from the Drive System to be held off after initial power up.
This allows the Drive System to fully enable prior to enabling the position loop.

Joystick Installed
Select “Yes” to enable the optional external Joystick. Not available for all control types and optional
control hardware required.

Speed Pot Installed
Select “Yes” to enable the optional external Speed Potentiometer. Not available for all control types
and optional control hardware required.