Hypertherm HTA Rev 6.00 Install Guide User Manual
Page 191
Appendix D: Edge™ Machine Interface
179
Oxy Fuel Pinout
Pin I/O
Description
10 Input
Oxygen
Cut
Sense
23 Input
Oxygen
Cut
Sense
11 Input
Program
Inhibit
24 Input
Program
Inhibit
3
Output NO
Oxygen Enable
4
Output COM
Oxygen Enable
8
Output NC
Oxygen Enable
32
Output NO
Oxygen Start
37
Output COM
Oxygen Start
36
Output NC
Oxygen Start
21 Output
NO
Preheat
22 Output
COM
Preheat
28 Output
NC
Preheat
9
Output NO
Plate Marker No. 1
15
Output COM
Plate Marker No. 1
14
Output NC
Plate Marker No. 1
1
115 V Hot
I/O Power Supply
18
I/O Shield
Chassis Ground
19
I/O Shield
Chassis Ground
34
115V Neutral I/O Power Supply Common
Plasma Pinout
Pin I/O
Description
5 Input Plasma
Select
18 Input
Plasma
Select
16
Input
Arc On Sense
29
Input
Arc On Sense
2
Output NO
Plasma Enable
3
Output COM
Plasma Enable
4
Output NC
Plasma Enable
22
Output NO
Plasma Start
21
Output COM
Plasma Start
15
Output NC
Plasma Start
37 Output
NO
Plasma
Height
36 Output
COM
Plasma
Height
35 Output
NC
Plasma
Height
26
Output NO
Plate Marker No. 2 or CNC Tracer
20
Output COM
Plate Marker No. 2 or CNC Tracer
13
Output NC
Plate Marker No. 2 or CNC Tracer