Storage environment, Electrical requirements, Power cord – Compuprint 4247-Z03 User Manual
Page 191
Storage environment
The following table shows the storage environment requirements for the printer.
Environment
Requirement
Temperature range
-35° to 65°C (-31° to 149°F)
Relative humidity range
5% to 95% RH (non-condensing)
Note:
Ribbon performance and print quality may degrade when exposed to
temperatures in excess of 41°C (105°F) for an extended period of time.
Electrical requirements
Use the following tables to plan your site power requirements. The tables list the
voltage inputs, grounding, plugs, and receptacles necessary for your new printer.
All voltages are single-phase.
Nominal Operation Voltages
Countries
100 V to 127 V 50 or 60 Hz
200 V to 240 V 50 or 60 Hz
United States, Canada
X
Central and South American,
and Far Eastern
X
X
European, Middle Eastern,
and African
Saudi Arabia, only
X
Power cord
DANGER
<1-11> Your country may require an approved power cord and plug.
Ensure that you have the correct power cord and plug. Use this cord and
plug only with an approved, correctly-installed power receptacle.
DANGER
DANGER<1-1> Do not use an extension power-cord.
Place the printer so the power cord can plug into the power receptacle without
putting stress on the power cord. The standard power cord length in the U.S. and
in all other countries is 2.74 m (9 ft). A 1.83 m (6 ft) power cord is also available in
the U.S.
Appendix A. Printer Specifications
175