3 configurations with 4 ports – BECKHOFF ET1100 User Manual
Page 30

Pin Description
III-16
Slave Controller
– ET1100 Hardware Description
3.2.2.3
Configurations with 4 ports
For configurations with 4 ports, logical ports 0 to 3 are used. The port signals are available at physical
ports 0 to 3, depending on the port configuration. P_MODE[1:0] has to be set to 11. P_CONF[3:0]
determine the physical layer of logical ports (3:0).
Table 16: Configurations with 4 ports (P_MODE[1:0]=01)
Logical port
Physical port
P_CONF
[3:0]
3
2
1
0
3
2
1
0
EBUS
(3)
EBUS
(2)
EBUS
(1)
EBUS
(0)
EBUS
(3)
EBUS
(2)
EBUS
(1)
EBUS
(0)
0000
EBUS
(3)
EBUS
(2)
EBUS
(1)
MII
(0)
EBUS
(3)
EBUS
(2)
EBUS
(1)
MII
(0)
0001
EBUS
(3)
EBUS
(2)
MII
(1)
EBUS
(0)
EBUS
(3)
EBUS
(2)
EBUS
(0)
MII
(1)
0010
EBUS
(3)
EBUS
(2)
MII
(1)
MII
(0)
EBUS
(3)
EBUS
(2)
MII
(1)
MII
(0)
0011
EBUS
(3)
MII
(2)
EBUS
(1)
EBUS
(0)
EBUS
(3)
EBUS
(1)
EBUS
(0)
MII
(2)
0100
EBUS
(3)
MII
(2)
EBUS
(1)
MII
(0)
EBUS
(3)
EBUS
(1)
MII
(2)
MII
(0)
0101
EBUS
(3)
MII
(2)
MII
(1)
EBUS
(0)
EBUS
(3)
EBUS
(0)
MII
(2)
MII
(1)
0110
EBUS
(3)
MII
(2)
MII
(1)
MII
(0)
EBUS
(3)
MII
(2)
MII
(1)
MII
(0)
0111
MII
(3)
EBUS
(2)
EBUS
(1)
EBUS
(0)
EBUS
(2)
EBUS
(1)
EBUS
(0)
MII
(3)
1000
MII
(3)
EBUS
(2)
EBUS
(1)
MII
(0)
EBUS
(2)
EBUS
(1)
MII
(3)
MII
(0)
1001
MII
(3)
EBUS
(2)
MII
(1)
EBUS
(0)
EBUS
(2)
EBUS
(0)
MII
(3)
MII
(1)
1010
MII
(3)
EBUS
(2)
MII
(1)
MII
(0)
EBUS
(2)
MII
(3)
MII
(1)
MII
(0)
1011
MII
(3)
MII
(2)
EBUS
(1)
EBUS
(0)
EBUS
(1)
EBUS
(0)
MII
(3)
MII
(2)
1100
MII
(3)
MII
(2)
EBUS
(1)
MII
(0)
EBUS
(1)
MII
(3)
MII
(2)
MII
(0)
1101
MII
(3)
MII
(2)
MII
(1)
EBUS
(0)
EBUS
(0)
MII
(3)
MII
(2)
MII
(1)
1110
MII
(3)
MII
(2)
MII
(1)
MII
(0)
MII
(3)
MII
(2)
MII
(1)
MII
(0)
1111