9.5

LVDS termination

The LVDS termination with an impedance of 100

Ω is typically achieved by a resistor R

L

=

100 Ω. It is

only necessary for EBUS ports and should be placed adjacent to the EBUS_RX inputs.

EBUS_RX-

EBUS_RX+

R

L

=

1

0

0

R

ET1100

R

L

I+

R

L

I-

V

CC I/O

Figure 49: LVDS termination

9.6

RBIAS resistor

The LVDS RBIAS resistor should have a value of R

BIAS

=

11 kΩ.

1

1

K

RBIAS

ET1100

Figure 50: LVDS load resistor

NOTE: If only MII ports are used (no EBUS at all), the RBIAS resistor can be selected in the range of 10-15 k

Ω.