Table 86: forwarding delays – BECKHOFF ET1100 User Manual
Page 112

Electrical Specifications and Timings
III-98
Slave Controller
– ET1100 Hardware Description
Table 86: Forwarding Delays
Symbol
Parameter
Min
Average
Max
Units
t
Diff
Average difference processing delay minus
forwarding delay (without RX FIFO jitter)
between any two ports
a) at least one of the two ports is EBUS
b) both ports are MII
a) 20
b) 40
ns
t
EE
EBUS port to EBUS port delay (FIFO size 7):
a) Through ECAT Processing Unit
(processing), Low Jitter off
b) Alongside ECAT Processing Unit
(forwarding), Low Jitter off
c) Through ECAT Processing Unit
(processing), Low Jitter on
d) Alongside ECAT Processing Unit
(forwarding), Low Jitter on
a) 140
b) 120
c) 150
d) 130
a) 150
b) 130
c) 155
d) 135
a) 160
b) 140
c) 160
d) 140
ns
t
EM
EBUS port to MII port delay
(FIFO size 7, TX Shift=00):
a) Through ECAT Processing Unit
(processing), Low Jitter off
b) Alongside ECAT Processing Unit
(forwarding), Low Jitter off
a) 145
b) 125
a) 170
b) 150
a) 195
b) 175
ns
t
ME
MII port to EBUS port delay
(FIFO size 7, TX Shift=00):
a) Through ECAT Processing Unit
(processing), Low Jitter off
b) Alongside ECAT Processing Unit
(forwarding), Low Jitter off
c) Through ECAT Processing Unit
(processing), Low Jitter on
d) Alongside ECAT Processing Unit
(forwarding), Low Jitter on
a) 255
b) 235
c) 265
d) 245
a) 280
b) 260
c) 290
d) 270
a) 305
b) 285
c) 315
d) 295
ns
t
MM
MII port to MII port delay
(FIFO size 7, TX Shift=00):
a) Through ECAT Processing Unit
(processing), Low Jitter off
b) Alongside ECAT Processing Unit
(forwarding), Low Jitter off
a) 280
b) 240
a) 305
b) 265
a) 335
b) 295
ns
NOTE: Average timings are used for DC calculations.