10 Electrical Specifications and Timings

10.1 Absolute Maximum Ratings

Table 80: Absolute Maximum Ratings

Symbol

Parameter

Condition

Min

Max

Units

V

CC I/O

-V

SS

Supply voltage for
internal LDO

-0.3

5.5

V

I

CC I/O

Supply current

Internal LDO for V

CC Core

used

a) V

CC I/O

=3.3V

b) V

CC I/O

=5V

a) 170
b) 220

mA

I

CC Core

Supply current

V

CC Core

sourced externally

150

mA

V

ESC

ESD protection

Human body model,
according to MIL-STD-883E-
3015.7 Class 1

2

kV

I

DC_ESD

Permanent current into
ESD protection diodes

Only in case of forward
biased ESD diodes. Input
voltage above V

CCI/O

or below

V

SS

2

mA

NOTE: Supply current does not include output driver current for PDIs and LEDs.

10.2 Electrical Characteristics

Table 81: Operating Conditions

Symbol

Parameter

Condition

Min

Typ

Max

Units

V

CC I/O

I/O power supply

3.0

3.3

5.5

V

V

CC Core

Logic power supply

2.25

2.5

2.75

V

V

CC PLL

PLL power supply

2.25

2.5

2.75

V

V

CC Core Ext

External logic power supply

2.5

2.5

2.75

V

V

CC PLL Ext

External PLL power supply

2.5

2.5

2.75

V

A

Ambient temperature

-40

85

°C