ATEIS DIVA8G2 User Manual
Page 265

System Functionality
265
© 2012 ATEÏS
Double click on the compressor/limiter icon, the compressor/limiter window pops up, see below.
Adjust the Compressor/Limiter parameters to suit your needs.
o
Type: Here you can choose between the compressor component or the limiter.
o
Bypass: Clicking on the bypass button will instantaneously bypass the compressor/limiter.
o
Soft Knee: If the soft knee button is pressed, the a soft knee will be applied to the
compressor/limiter instead of a hard knee.
o
Compressing: In case of compressor, this will indicates if the compression is acting or not.
o
Limiting: In case of limiter, this will indicates if the limiter is acting or not.
o
Ratio(Comp)x:1: Here you can specify the compression ratio either by using the slide bar,