ATEIS DIVA8G2 User Manual
Page 183

System Functionality
183
© 2012 ATEÏS
1K monitoring will cause high pitch sounds.
Leakage Detection Control:
o
M/S Amplifier Share: If there are more than one devices, this box should be ticked.
Monitor Control
o
HW Observer Mode: If enabled, this options in combination with the "Monitor device" drop-
down menu allows to block the monitoring process on one device. This option has been
designed only for commissioning and maintenance purposes.
Warning: as soon as maintenance tests are finished, you have to disable the "HW
Observer Mode" option.
o
Current Monitor Target ID: Displays the current monitored device. In "Periodic" monitoring
mode, you should see the display going from Master DIVA to each Slave unit. In "HW
Observer Mode", you should only see the device selected with in "Monitor device" drop-down
menu.
Zone Monitoring
Zone Monitoring display:
Zone: Displays the zone number.
ReferenceA (Ohm): Displays the value taken as reference for line A of one zone.
ReferenceB (Ohm): Displays the value taken as reference for line B of one zone.
RefereneA/B (Ohm): Displays the value taken as reference for A and B in parallel.
Connected Source: Display the source connected to one zone (Voice Amplifier, Music
Amplifier, VO3).
Tolerance (%): Here you can specify the tolerance wherein measurement has to stay before
generating a fault state.
Measure (Ohm): Displays the real time measurement of A and B in parallel.
Diff (%): Displays the difference in percent between Reference A/B and Measure.
Zone Monitoring Controls:
Get Reference: This button start the get reference process for one zone at a time
Get all Reference: This button start the get reference process for all zone
Reset Reference: This button allows to reset all reference stored
Reset Monitoring: This button allows to reset the monitoring in case of maintenance
Procedure to make references for one zone, please follow the next steps:
o
Select a zone by clicking on the corresponding line.
o
Press the "Get Reference" button.
o
Choose a tolerance value.
Procedure to make references for all zone, please do so: