System Functionality
179
© 2012 ATEÏS
Tick the check box in order to enable the relay.
Set the contact pulse length, range 50ms to 6000ms.
Select on each device (master and/or slaves) the output channel that will be used as Start
Impulse contact. Note: multiple output channels can be selected for an event.
Use Bypass Relay
The bypass relays are independent of events. The goal of bypass relay is to close/open a relay when
some zone(s) are occupied with a type of source.
In order to set a bypass relay, follow the next few steps:
Go in menu View -> GPIO -> Bypass Relay tab
o
Channel 1 to 8: Correspond to the output channel.
o
Activations: Specify if the contact will be closed when active or opened when active.
o
Settings: By clicking on the edit button, you will enter the zone/source matrix.