beautypg.com

5 firmware command buffer, 5 standard commands – Artesyn MVME51005E SBC Installation and Use (July 2014) User Manual

Page 58

background image

PPCBug Firmware

MVME51005E Single Board Computer Installation and Use (6806800A38D)

60

3.4.5

Firmware Command Buffer

Firmware Command Buffer Enable = N?

Firmware Command Buffer Delay = 5?

Defines the number of seconds to wait before firmware begins executing the startup
commands in the startup command buffer. During this delay, you may press any key to prevent
the execution of the startup command buffer.

The default value of this parameter causes a startup delay of 5 seconds.

Firmware Command Buffer:

['NULL' terminates entry]?

The Firmware Command Buffer contents contain the BUG commands which are executed
upon firmware startup.

BUG commands you place into the command buffer should be typed just as you enter the
commands from the command line.

The string 'NULL' on a new line terminates the command line entries.

All PPCBug commands, except for the following, may be used within the command buffer: DU,
ECHO, LO, TA, VE.

Note: Interactive editing of the startup command buffer is not supported. If changes are
needed to an existing set of startup commands, a new set of commands with changes must be
reentered.

3.5

Standard Commands

The individual debugger commands are listed in the following table. The commands are
described in detail in the PPCBug Firmware Package User’s Manual, listed in

Appendix D,

Related Documentation

.

Y

Enables Firmware Command Buffer execution.

N

Disables Firmware Command Buffer execution (Default).