Ppcbug firmware – Artesyn MVME51005E SBC Installation and Use (July 2014) User Manual
Page 46

PPCBug Firmware
MVME51005E Single Board Computer Installation and Use (6806800A38D)
48
Field Service Menu Enable [Y/N] = N?
Remote Start Method Switch [G/M/B/N] = B?
The Remote Start Method Switch is used when the MVME5100 is cross-loaded from another
VME-based CPU in order to start execution of the cross-loaded program.
Probe System for Supported I/O Controllers [Y/N] = Y?
Auto-Initialize of NVRAM Header Enable [Y/N] = Y?
Y
Display the field service menu.
N
Do not display the field service menu. (Default)
G
Use the Global Control and Status Register to pass and start
execution of the cross-loaded program.
M
Use the Multiprocessor Control Register (MPCR) in shared RAM to
pass and start execution of the cross-loaded program.
B
Use both the GCSR and the MPCR methods to pass and start
execution of the cross-loaded program. (Default)
N
Do not use any Remote Start Method.
Y
Accesses will be made to the appropriate system buses (for
example, VMEbus, local MPU bus) to determine the presence of
supported controllers. (Default)
N
Accesses will not be made to the VMEbus to determine the
presence of supported controllers.
Y
NVRAM (PReP partition) header space will be initialized
automatically during board initialization, but only if the PReP
partition fails a sanity check. (Default)
N
NVRAM header space will not be initialized automatically during
board initialization.