beautypg.com

1 base channel phys, Functional description – Artesyn ATCA-F125 Installation and Use Guide (April 2014) User Manual

Page 78

background image

Functional Description

ATCA-F125 (6873M Artwork) Installation and Use (6806800J94J)

78

Port 0-16 of the base channel switch are configured as SGMII interfaces, so they can support
auto-negotiation. Ports 17-23 can be either configured as SGMII or SERDES channels. Port
configuration is done by software.

4.7.1

Base Channel PHYs

The ATCA-F125 uses two Broadcom BCM54680 octal PHYs, a BCM54616S PHY, and a
BCM8747 PHY for the base channel. Each BCM54680 supports eight SGMII channels to the
BCM56334 and provides the physical layer functions for the 10/100/1000Base-T connections
or 10/100-T connections to the backplane. The BCM54616S PHY is a single PHY that supports
an SGMII channel to the BCM56334 and provides the physical layer functions for a
10/100/1000 Base-T connection to the backplane.

The BCM8747 PHY is a four port XAUI to 10 Gb SFI PHY that provides the interface between
two of the Base Switch 10 GbE stacking ports and the front panel SFP+ modules. The other two
ports of the BCM8747 PHY provide the interface between two of the Fabric Switch 10 GbE
stacking ports and the front panel SFP+ modules. The BCM8747 requires an external SPI flash
device to load microcode into the device. An AT25256B or equivalent SPI flash device is used
for this purpose.

22

-

BIX-RTM

ETH3

SGMII

23

-

BIX-RTM

ETH4

SGMII

HG-
0

BIX_XGMDIO/BIX_X
GMDC

22

BCM8747-2 on
RTM

BIX- RTM ETH6

XAUI

HG-
1

BIX_XGMDIO/BIX_X
GMDC

23

BCM8747-2 on
RTM

BIX-RTM ETH5

XAUI

HG-
2

BIX_XGMDIO/BIX_X
GMDC

24

BCM8747

BIX- Front ETH1

XAUI

HG-
3

BIX_XGMDIO/BIX_X
GMDC

25

BCM8747

BIX-Front ETH2

XAUI

Table 4-3 BCM56344 Base Channel Switch Connections (continued)

Port

Base
Channel

Management
Interface

PHY
ADDR/
Front
Board

CONNECTED TO
PHY

CONNECTION BETWEEN

LINK TYPE