Power Requirements

The blade's power requirements depend on the installed hardware accessories. To install the
accessories on the blade, the load of the respective accessory has to be added to that of the
blade. The following table show typical examples of the power requirements, with and without
accessories installed. For information on the accessories' power requirements, refer to the
documentation delivered together with the respective accessory or consult your local Artesyn
Embedded Technologies representative for further details.

The blade must be connected to a TNV-2 or a safety-extra-low-voltage (SELV) circuit. A TNV-2
circuit is a circuit whose normal operating voltages exceed the limits for a SELV circuit under
normal operating conditions, and which is not subject to overvoltages from
telecommunication networks.

Table 2-2 Power Requirements

Characteristic

Value

Rated Voltage Exception in the US and Canada

-48 VDC to -60 VDC, US and -48 VDC,
Canada

Operating Voltage Exception in the US and Canada

-39 VDC to -72 VDC, US and -39 VDC to
-60 VDC, Canada

Max. power consumption of ATCA-F125 with SATA
drive and RTM-ATCA-F125

125 W (98 W typical)

Max. power consumption of ATCA-F125 with SATA
drive (without RTM-ATCA-F125)

105 W (80 W typical)