Table 4-3, Bcm56344 base channel switch connections, Functional description – Artesyn ATCA-F125 Installation and Use Guide (April 2014) User Manual
Page 77

Functional Description
ATCA-F125 (6873M Artwork) Installation and Use (6806800J94J)
77
The table below lists each BCM56334 port by number, the device to which it is connected, and
the connection type utilized.
Table 4-3 BCM56344 Base Channel Switch Connections
Port
Base
Channel
Management
Interface
PHY
ADDR/
Front
Board
CONNECTED TO
PHY
CONNECTION BETWEEN
LINK TYPE
0
3
BIX_MDIO/BIX_MDC 1
BCM54680-1
BIX - Backplane Channel 3
1000B-T
1
4
BIX_MDIO/BIX_MDC 2
BCM54680-1
BIX - Backplane Channel 4
1000B-T
2
5
BIX_MDIO/BIX_MDC 3
BCM54680-1
BIX - Backplane Channel 5
1000B-T
3
6
BIX_MDIO/BIX_MDC 4
BCM54680-1
BIX - Backplane Channel 6
1000B-T
4
7
BIX_MDIO/BIX_MDC 5
BCM54680-1
BIX - Backplane Channel 7
1000B-T
5
8
BIX_MDIO/BIX_MDC 6
BCM54680-1
BIX - Backplane Channel 8
1000B-T
6
9
BIX_MDIO/BIX_MDC 7
BCM54680-1
BIX - Backplane Channel 9
1000B-T
7
10
BIX_MDIO/BIX_MDC 8
BCM54680-1
BIX - Backplane Channel 10
1000B-T
8
11
BIX_MDIO/BIX_MDC 9
BCM54680-2
BIX - Backplane Channel 11
1000B-T
9
12
BIX_MDIO/BIX_MDC 10
BCM54680-2
BIX - Backplane Channel 12
1000B-T
10
13
BIX_MDIO/BIX_MDC 11
BCM54680-2
BIX - Backplane Channel 13
1000B-T
11
14
BIX_MDIO/BIX_MDC 12
BCM54680-2
BIX - Backplane Channel 14
1000B-T
12
15
BIX_MDIO/BIX_MDC 13
BCM54680-2
BIX - Backplane Channel 15
or RTM
1000B-T
13
16
BIX_MDIO/BIX_MDC 14
BCM54680-2
BIX - Backplane Channel 16
or Service Proc eTSEC3
1000B-T
14
1A
BIX_MDIO/BIX_MDC 15
BCM54680-2
BIX - BC 1A
10/100B-T
15
1B
BIX_MDIO/BIX_MDC 16
BCM54680-2
BIX - BC 1B
10/100B-T
16
2
BIX_MDIO/BIX_MDC 0
BCM54616S-1
BIX-BC 2
1000B-T
17
-
BIX-PrAMC/P0
SERDES
18
-
BIX X-connect or RTM
SGMII
19
17
BCM54616S to
TopSync
Clock TopSync or RTM
SGMII
20
-
BIX-RTM
ETH1
SGMII
21
-
BIX-RTM
ETH2
SGMII