Etup, Nstallation and, Ower – Doremi ShowVault / IMB User Manual
Page 242: Equence, 2 hfr setup, 3 non-hfr setup, 4 installation and power-up sequence

____________________________________________________________________________________
SHV.OM.001663.DRM
Page 242 of 276
Version 1.7
Doremi Labs
22.2 HFR Setup
For HFR setups, the user must be running software version 2.6.3 or higher.
Primary IMB (SM):
Firmware: 32.07d or higher.
Alternative Firmware: 32.06z or higher.
Security Manager: 5.1.4 or higher.
Secondary IMB (LD):
Firmware: 33.05k or higher.
Alternative Firmware: 33.07a or higher.
Security Manager: 5.1.4 or higher.
22.3 Non-HFR Setup
For non-HFR setups, the user must be running software version 2.6.3 or higher.
Primary IMB (SM):
Firmware: 32.07d or higher.
Security Manager: 5.1.4 or higher.
Secondary IMB (LD):
Firmware: 33.05k or higher.
Security Manager: 5.1.4 or higher.
22.4 Installation and Power-Up Sequence
Installation:
Verify that both projectors and the ShowVault are turned off.
Install the IMB-SM in the primary projector.
Install the IMB-LD in the secondary projector.
Connect Ethernet cables to both projectors and the ShowVault and verify that they are
on the same network.
Connect the PCI-express cable from the ShowVault to the IMB-SM (primary projector).
Connect BNC cables (A and B) fr
om the Primary Projector’s SDI-out connectors to the
Secondary Projector’s SDI-In connectors (Figure 319).